Please notice the following:
KU PA BB 005090-6 A - RF Power Amplifier
50 ... 900 MHz • 6 W
Available from stock
Technical specifications
| Frequency range | 50..900 MHz |
| Input power for P1dB | typ. +3 dBm |
| Maximum input power | +10 dBm |
| Output power P1dB | typ. 37.8 dBm, min. 37 dBm (CW) (50 ... 500 MHz) |
| typ. 36 dBm, min. 34.7 dBm (CW) (500 ... 900 MHz) | |
| Output power P1dB | typ. 6 W, min. 5 W (CW) (50 ... 500 MHz) |
| typ. 4 W, min. 3 W (CW) (500 ... 900 MHz) | |
| Output power P3dB | typ. 39 dBm, min. 38.4 dBm (CW) (50 ... 500 MHz) |
| typ. 37.8 dBm, min. 37 dBm (CW) (500 ... 900 MHz) | |
| Output power P3dB | typ. 8 W, min. 7 W (CW) (50 ... 500 MHz) |
| typ. 6 W, min. 5 W (CW) (500 ... 900 MHz) | |
| Output power COFDM (1) | min. 30 dBm |
| min. 1 W | |
| Gain (small signal) | min. 31.5 dB |
| Gain flatness (small signal) | typ. +/- 2.5 dB |
| Harmonic rejection | typ. 20 dB, min. 18 dB @ 37 dBm |
| IM3 (2) | typ. 30 dBc, min. 23 dBc @ 37 dBm PEP |
| Efficiency | min. 20 % @ 37 dBm (CW) |
| Input return loss (S11) | min. 13 dB |
| ON voltage | +9 ... 14 V DC |
| Supply voltage | +28 V DC |
| Quiescent current | typ. 0.5 A |
| Current consumption | max. 1.1 A |
| Operating case temp. range | -20 ... +55 °C |
| VSWR of load | max. 1.8 : 1 |
| Input connector / impedance | SMA-female / 50 ohms |
| Output connector / impedance | SMA-female / 50 ohms |
| Case | milled aluminium |
| Dimensions (mm) | 80 x 60 x 20 |
| Weight | 135 g (typ.) |
| (1) | Measured with QAM 64, single carrier, EVM: 2% |
| (2) | Measured 2-tone, frequency spacing: 1 MHz |
Features
- LD MOSFET technology
- Reverse polarity protection
- Milled aluminium case
- Small mechanical dimensions
Applications
- Analog transmission systems
- Measurement and laboratory equipment
- Driver amplifier
Important notes
Please notice the following:
- The technical specifications refer to room temperature.
- The power amplifier doesn’t contain any coaxial relays.
- The recommended combination of heat sink and fan(s) is only specified for an ambient temperature of 25 °C.
- Further information about dimensioning of heat sinks is available on our FAQ site.