KU PA 014018-50 HY, RF Power Amplifier
140 ... 180 MHz • 50 W
Lead time on request
Technical specifications
Frequency range | 140..180 MHz |
Input power for P3dB | min. +12 dBm |
Maximum input power | +17 dBm |
Output power P3dB | typ. 47 dBm, min. 46.5 dBm |
typ. 50 W, min. 45 W | |
Gain (small signal) | typ. 36 dB, min. 34 dB |
Gain flatness (small signal) | typ. +/- 3 dB |
Harmonic rejection | typ. 50 dB @ 47 dBm |
IM3 (1) | min. 20 dBc @ 43 dBm PEP |
Efficiency | min. 30 % @ 47 dBm (CW) |
Input return loss (S11) | typ. 10 dB |
ON voltage | +12 V DC |
Supply voltage | +12 ... 14 V DC |
Quiescent current | typ. 4 A |
Current consumption @ P3dB | max. 12 A |
Forward detection | yes (diode detector) |
Reflected power detection | yes (diode detector) |
Operating case temp. range | -20 ... +55 °C |
VSWR of load | max. 1.8 : 1 |
Input connector / impedance | SMA-female / 50 ohms |
Output connector / impedance | N-female / 50 Ohms |
Case | milled aluminium |
Dimensions (mm) | 130 x 60 x 20 |
Weight | 270 g (typ.) |
(1) | Measured 2-tone, frequency spacing: 1 MHz |
Features
- Built-in low pass filter for good harmonic rejection
- Reverse polarity protection
- Monitor outputs for forward and reverse power detection
Applications
- Analog transmission systems
Important notes
Please notice the following:
- All technical data specified at a supply voltage of 14
- The power amplifier doesn’t contain any coaxial relays.
- The recommended combination of heat sink and fan(s) is only specified for an ambient temperature of 25 °C.
- Further information about dimensioning of heat sinks is available on our FAQ site. V DC at room temperature
Downloads